Evaluation of three rapid tests for diagnosis of P. falciparum and P. vivax malaria in Colombia.

van den Broek I Hill O Gordillo F Angarita B Hamade P Counihan H Guthmann JP
The American journal of tropical medicine and hygiene 2006 Dec ; 75(6); 1209-15. doi: . Epub 2007 04 04

Abstract

The diagnostic capacity of three malaria rapid diagnostic tests (RDTs), NOW-Malaria-ICT, OptiMAL-IT, and Paracheck-Pf, was evaluated against expert microscopy in Colombia. We tested 896 patients, of whom microscopy confirmed 139 P. falciparum, 279 P. vivax, and 13 mixed P.f/P.v infections and 465 negatives. Paracheck-Pf and NOW-malaria-ICT were more accurate in detecting P. falciparum (sensitivities 90.8% and 90.1%, respectively) in comparison with Optimal-IT (83.6%). NOW showed an acceptable Pf detection rate at low densities (